Monday, October 26, 2026

DIY Series 107: Repair Cornell Ceramic Cooker (CCC-2201X)

Cornell Ceramic Cooker (CCC-2201X) is a 2000W multi-function kitchen appliance featuring a digital touch panel.

Symptoms:

  • Having "E1" Error (High Temperature) displayed on the touch panel screen.

Findings: 

  • Thermocouple broken (having open loop connectivity)

Photos:

  1. Cornell Ceramic Cooker (Model: CCC-2201X)
  2. Dismantle at bottom side with unscrew 7 pcs of screws. Turn back the cooker facing up, remove the glass top surface. 
  3. Unscrew 1 screw to take out the control panel board.
  4. Unscrew 3 screws to dismantle the heating element.
  5. Remove the 3pcs plastic holders of heating element.
  6. Unplug the broken thermocouple from the main board.
  7. Unscrew 2 screws at the bottom of heating element to remove thermocouple for its holder.
  8. Install new thermocouple onto the main board.








Video:

  1. Cornell Ceramic Cooker having "E1" Error.
  2. Cornell Ceramic Cooker after fixing done.



Tools required:


Costs involved:

No comments: