Cornell Ceramic Cooker (CCC-2201X) is a 2000W multi-function kitchen appliance featuring a digital touch panel.
Symptoms:
- Having "E1" Error (High Temperature) displayed on the touch panel screen.
Findings:
- Thermocouple broken (having open loop connectivity)
Photos:
- Cornell Ceramic Cooker (Model: CCC-2201X)
- Dismantle at bottom side with unscrew 7 pcs of screws. Turn back the cooker facing up, remove the glass top surface.
- Unscrew 1 screw to take out the control panel board.
- Unscrew 3 screws to dismantle the heating element.
- Remove the 3pcs plastic holders of heating element.
- Unplug the broken thermocouple from the main board.
- Unscrew 2 screws at the bottom of heating element to remove thermocouple for its holder.
- Install new thermocouple onto the main board.
Video:
- Cornell Ceramic Cooker having "E1" Error.
- Cornell Ceramic Cooker after fixing done.
Tools required:
Costs involved:
- Thermocouple (2pcs): ~US$2.50








No comments: