Repair Ariston Water Heater (FE-3624ESP)
Symptoms:
- Upon power on, the ELCB (Green LED) is ON, but the Power (Red LED) is OFF.
- The water flow out is not warm / hot at all.
Analysis:
- The water flow sensor (magnet) was rusted and cracked, causing intermittent connectivity to Reed Switch when water flow in.
- The Power Supply Board having a bulging capacitor (400V, 68uF, 105°C), and the lead at the bottom having signs of leaking.
- After fixed the magnet sensor and the bulging capacitor, if the Power (Red LED) is still OFF, press RESET button (Caution: Do it only when the water heater is power off) on the thermostat (located on top of the heater tank) to resume the operation of water heater.
Photos:
- Ariston Water Heater
- Ariston Model FE-3624ESP
- After dismantling the front cover
- Location of the flow sensor (magnet) and Reed Switch
- Universal magnet sensor (replacement)
- Location of the Power Supply Board
- Bulging capacitor
- Leaking at the capacitor
- Reset the thermostat (if needed) at the top of heater tank
Tools required:
- Screwdriver
- Multimeter
- Soldering Tools
Costs involved:
- Flow sensor (magnet): ~US$2.50
- Capacitor (400V, 68uF, 105°C): US$1.00 ~ US$2.00









No comments: